Skip to content

Description

Specifications

Dimensions

Ordering Info

Downloads

Description

Path 7

Description

Specifications

Dimensions

Ordering Info

Downloads

Description

Design Features

  • Provides AC or DC bus supply voltages for up to four Aerotech controllers
  • 300 watts max power output (TM3); 500 watts max power output (TM5)
  • Auxiliary supply outputs for powering up to four additional products

TM3 Transformer Module

The TM3 transformer module is configured at the factory to provide 28 VAC, 56 VAC, 115 VAC, 40 VDC, 80 VDC or 160 VDC with a maximum transformer output power capability of 300 watts.

Additionally, the TM3 provides auxiliary supply outputs for powering the auxiliary power inputs of up to four Aerotech products. The TM3 also includes a 24 VDC power supply that provides the user with 24 VDC output. Other features of the TM3 include a soft-start circuit to limit inrush current and a voltage selector that can be configured for AC input voltages of 100 VAC, 115 VAC, 200 VAC, or 230 VAC.

TM5 Transformer Module

The TM5 transformer module is configured at the factory to provide 28 VAC, 56 VAC, 115 VAC or a combination of these voltages with a total output power capability of 500 watts. Additionally, the TM5 distributes the applied AC line voltage to each of the auxiliary supply outputs for powering the auxiliary power inputs of other Aerotech products. The TM5 may also be purchased with the 24 VDC power supply option that provides the user with 24 VDC output.

TM Series Specifications

Model
TM3
TM5
Type Isolation Isolation
AC Input Configurations 100 VAC, 115 VAC, 200 VAC, 230 VAC 100 VAC, 115 VAC, 200 VAC, 230 VAC
Peak AC Input
Inrush Current
32 Apk 200 Apk
Operating Frequency 50/60 Hz 50/60 Hz
Maximum Continuous Transformer Output Power 300 watts max @ 20°C 500 watts max @ 20°C
Peak Transformer
Output Power
400 watts max @ 20°C 800 watts max @ 20°C
Short Circuit/Over
Current Protection
AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 3 A slow-blow fuse connected to transformer primary winding AC input 10 A breaker/switch (supplementary protection only); 100 VAC/115 VAC configurations contain 8 A slow-blow fuse connected to transformer primary winding; 200 VAC/230 VAC configurations contain 4 A slow-blow fuse connected to transformer primary winding
Thermal Protection Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C. Integral transformer thermal switch is normally closed. Thermal switch opens when internal temperature of transformer reaches 110°C.
Secondary Winding Configuration 28 VAC (40 VDC bus); 56 VAC (80 VDC bus); ±10 VDC, ±20 VDC, ±30 VDC, ±40 VDC 28 VAC (40 VDC bus); 56 VAC (80 VDC bus); 112 VAC (160 VDC bus)
+24 VDC Output 4 A max 4 A max

Dimensions

TM3 Transformer



TM5 Transformer



Ordering Information

TM3/TM5 Transformers

Option Description
TM3 0.3 kVA Isolation Transformer
TM5 0.5 kVA Isolation Transformer

Line Voltage (Required)

Option Description
-A 115 VAC Input Line Voltage
-B 230 VAC Input Line Voltage
-C 100 VAC Input Line Voltage
-D 200 VAC Input Line Voltage

Output Bus Voltage (Required)

Option Description
-28VAC-28VAC(1)(2) VBus1 / VBus2: 28 VAC for 40 VDC Bus
-56VAC-56VAC(1)(2) VBus1 / VBus2: 56 VAC for 80 VDC Bus
-40VDC-40VDC(1) VBus1 / VBus2: 40 VDC
-80VDC-80VDC(1) VBus1 / VBus2: 80 VDC
-40B-40B(1) VBus1 / VBus2: +/- 40 VDC
-30B-30B(1) VBus1 / VBus2: +/- 30 VDC
-20B-20B(1) VBus1 / VBus2: +/- 20 VDC
-10B-10B(1) VBus1 / VBus2: +/- 10 VDC
-40BAUXAC-40BAUXAC(1) VBus1 / VBus2: +/- 40 VDC w/ Aux AC
-28VAC-56VAC(2) VBus1: 28 VAC, VBus2: 56 VAC, for 40/80 VDC Bus
-56VAC-28VAC(2) VBus1: 56 VAC, VBus2: 28 VAC, for 80/40 VDC Bus
-56VACCT-28VAC(2) VBus1: 56 VAC Center Tap, VBus2: 28 VAC, for 80/40 VDC Bus
-56VACCT-56VAC(2) VBus1: 56 VAC Center Tap, VBus2: 56 VAC, for 80 VDC Bus
-28VAC-56VACCT(2) VBus1: 28 VAC, VBus2: 56 VAC Center Tap, for 40/80 VDC Bus
-56VAC-56VACCT(2) VBus1: 56 VAC, VBus2: 56 VAC Center Tap, for 80 VDC Bus
-56VACCT-56VACCT(1)(2) VBus1 / VBus2: 56 VAC Center Tap, for 80 VDC Bus
-115VAC-115VAC(2) VBus 1 / VBus2: 115 VAC, for 160 VDC Bus
Notes:
  1. Available with TM3 Transformers
  2. Available with TM5 Transformers

Bus Split

Option Description
/1-3(2) VBus1 on Output 1, VBus 2 on Output 2, 3, and 4
/2-2(1)(2) VBus1 on Output 1 and 2, VBus 2 on Output 3 and 4
/3-1(2) VBus1 on Output 1, 2, and 3, VBus2 on Output 4
/NOSPLIT(1)(2) VBus1 and VBus2 Tied Together and Wired to All Axes
Notes:
  1. Available with TM3 Transformers
  2. Available with TM5 Transformers

Power Supply

Option Description
/PS24-1 24 VDC, 4 A Power Supply for Brake Control

Brake Cable

Option Description
/C24-06 0.6 m (2 ft) Two Conductor Brake Cable with Flying Leads
/C24-09 0.9 m (3 ft) Two Conductor Brake Cable with Flying Leads
/C24-12 1.2 m (4 ft) Two Conductor Brake Cable with Flying Leads
/C24-15 1.5 m (5 ft) Two Conductor Brake Cable with Flying Leads
/C24-18 1.8 m (6 ft) Two Conductor Brake Cable with Flying Leads

Output 1 Cable*

* Output 2, Output 3, and Output 4 cables have the same available options. The options codes are identical except that they begin with C2 for Output 2, C3 for Output 3, and C4 for Output 4.

Option Description
/C1AB-06(1)(2) Cable, 0.6 m (2 ft) - Control and Bus for HPe/CP Drive
/C1AB-09(1)(2) Cable, 0.9 m (3 ft) - Control and Bus for HPe/CP Drive
/C1AB-12(1)(2) Cable, 1.2 m (4 ft) - Control and Bus for HPe/CP Drive
/C1AB-15(1)(2) Cable, 1.5 m (5 ft) - Control and Bus for HPe/CP Drive
/C1AB-18(1)(2) Cable, 1.8 m (6 ft) - Control and Bus for HPe/CP Drive
/C1AL-06(1) Cable, 0.6 m (2 ft) - Control and Bus for GCL
/C1AL-09(1) Cable, 0.9 m (3 ft) - Control and Bus for GCL
/C1AL-12(1) Cable, 1.2 m (4 ft) - Control and Bus for GCL
/C1AL-15(1) Cable, 1.5 m (5 ft) - Control and Bus for GCL
/C1AL-18(1) Cable, 1.8 m (6 ft) - Control and Bus for GCL
/C1AM-06(1) Cable, 0.6 m (2 ft) - Control and Bus for MP Drive
/C1AM-09(1) Cable, 0.9 m (3 ft) - Control and Bus for MP Drive
/C1AM-12(1) Cable, 1.2 m (4 ft) - Control and Bus for MP Drive
/C1AM-15(1) Cable, 1.5 m (5 ft) - Control and Bus for MP Drive
/C1AM-18(1) Cable, 1.8 m (6 ft) - Control and Bus for MP Drive
/C1ML-06(1) Cable, 0.6 m (2 ft) - Control and Bus for ML Drive
/C1ML-09(1) Cable, 0.9 m (3 ft) - Control and Bus for ML Drive
/C1ML-12(1) Cable, 1.2 m (4 ft) - Control and Bus for ML Drive
/C1ML-15(1) Cable, 1.5 m (5 ft) - Control and Bus for ML Drive
/C1ML-18(1) Cable, 1.8 m (6 ft) - Control and Bus for ML Drive
Notes:
  1. Available with TM3 Transformers
  2. Available with TM5 Transformers

Line Cord

Option Description
/US115VAC US 115 VAC Compatible Line Cord
/US230VAC US 230 VAC Compatible Line Cord
/ENGLAND U.K. Compatible Line Cord
/GERMANY German Compatible Line Cord
/ISRAEL Israel Compatible Line Cord
/INDIA India Compatible Line Cord
/AUSTRALIA Australia Compatible Line Cord